E2402: Negative pressure wound therapy pump. What Medicare needs on the order
E2402 is a negative pressure wound therapy (NPWT) pump, stationary or portable. Medicare covers it for qualifying chronic ulcers after a full wound care program, and for certain surgical or traumatic wounds, with monthly wound measurements and a 4-month limit per wound.
HCPCS E2402
- Official description
- Negative pressure wound therapy electrical pump, stationary or portable
- Short descriptor
- Neg press wound therapy pump
- Medicare policy
- LCD L33821, article A52511
- Payment
- Capped rental: rented for up to 13 months, then the patient owns it
- Prior authorization
- Not required by Medicare
- Face-to-face and order before delivery
- Not on the CMS list
- Last checked
- November 11, 2026
What the code covers
E2402 is an electric pump that applies controlled suction to a wound to remove fluid and debris, and can switch between continuous and intermittent modes. It works as a system with dressing sets (A6550) and canisters (A7000). Only products that the PDAC contractor has verified and listed for E2402 may be billed with it. One pump can treat several wounds, so more than one E2402 for the same period is denied.
When Medicare covers it
The pump and supplies are covered when criterion A or B is met.
A. Ulcers and wounds at home. The patient has a chronic Stage 3 or 4 pressure ulcer, a neuropathic (for example, diabetic) ulcer, a venous or arterial insufficiency ulcer, or a chronic ulcer of mixed cause present for at least 30 days. Before NPWT, a complete wound therapy program must have been tried, or considered and ruled out:
- For every wound: evaluation, care and wound measurements by a licensed medical professional, moist dressings, debridement of dead tissue if present, and attention to nutrition.
- Stage 3 or 4 pressure ulcers: turning and positioning, a group 2 or 3 support surface for ulcers on the back or pelvis, and moisture and incontinence managed.
- Neuropathic ulcers: a comprehensive diabetes management program and pressure taken off the foot ulcer.
- Venous insufficiency ulcers: compression bandages or garments used consistently, and leg elevation and walking encouraged.
B. Wounds first treated in the hospital. NPWT started in an inpatient setting for one of the wounds above after other treatments were tried or ruled out, or a complication of a surgical wound (such as dehiscence) or a traumatic wound where faster granulation is medically necessary. Either way, it is covered when treatment is ordered to continue at home.
Never covered when the wound has dead tissue with eschar and debridement was not attempted, untreated osteomyelitis near the wound, cancer in the wound, or an open fistula to an organ or body cavity near the wound.
Continued coverage needs a licensed medical professional to assess the wound regularly, supervise or do the dressing changes, and document changes in the wound’s size and characteristics at least monthly. Coverage ends when that stops, when the wound has healed enough, when there was no measurable healing over the prior month, when the pump is no longer used, or after 4 months on the most recent wound, including time used in the hospital.
What the order and records need
- A standard written order with the patient’s name or MBI, the order date, the pump and supplies, the quantities, and the treating practitioner’s name or NPI and signature.
- A statement from the treating practitioner describing the wound at the start, with measurements, and the wound care tried under criterion A.
- Monthly measurements of length, width and depth, and the amount of drainage, compared like with like from month to month. The supplier must get an assessment of healing progress from the treating clinician.
- The first inpatient date of NPWT, if it started in the hospital.
- Proof of delivery.
Medicare does not require prior authorization or a face-to-face list encounter for E2402.
Modifiers
- RR with KH, KI and KJ for the rental months.
- KX only when all criteria are met. KX must not be used from the fifth month on a single wound, or the fifth month after therapy began on the most recent wound. GA or GZ when criteria are not met. Lines without KX, GA or GZ are rejected.
Rental or purchase
E2402 is a capped rental item on the DMEPOS fee schedule. Supplies are limited to 15 dressing sets per wound per month and 10 canisters per month, unless the record shows heavy drainage of more than 90 ml a day.
Why claims get denied
- The wound care program before NPWT is not documented, or the wound type does not qualify. These are medical necessity denials like CO-50.
- Monthly measurements are missing, or show no healing over the prior month.
- Claims past 4 months on the same wound. The Policy Article says one more month at a time can be requested through the appeals process, starting with a redetermination, with records explaining why.
- A pump that is not on the PDAC list for E2402, or more than one pump at a time.
- KX on a fifth or later month, or a missing modifier. See CO-4, and MA130 for claims returned as unprocessable.
Sources
Last checked November 11, 2026 against the documents below. These are the Medicare fee-for-service rules that the DME MACs (Noridian and CGS) apply. Medicare Advantage plans, Medicaid and commercial payers set their own rules, so requirements can differ by payer. Policies change, so check the current version before you rely on a detail.
- LCD L33821: Negative Pressure Wound Therapy Pumps
- Policy Article A52511: Negative Pressure Wound Therapy Pumps
- CGS documentation checklist: Negative pressure wound therapy pumps
- Policy Article A55426: Standard Documentation Requirements for All Claims Submitted to DME MACs
- CMS HCPCS quarterly update (official code descriptors)
- CMS DMEPOS fee schedule (payment category of each code)
- CMS Required Prior Authorization List
- CMS Required Face-to-Face Encounter and Written Order Prior to Delivery List
Run your revenue cycle as workflows.
We are working with a small group of billing and operations teams to shape worklist. Tell us where your work gets stuck, and we'll show you how it would run.