E0470: BiPAP device without backup rate. What Medicare needs on the order
E0470 is a bi-level respiratory assist device without a backup rate, often called BiPAP. For obstructive sleep apnea, Medicare covers it only after a CPAP (E0601) was tried and proven ineffective. Other conditions fall under a separate respiratory assist device policy.
HCPCS E0470
- Official description
- Respiratory assist device, bi-level pressure capability, without backup rate feature, used with noninvasive interface, e.g., nasal or facial mask (intermittent assist device with continuous positive airway pressure device)
- Short descriptor
- Rad w/o backup non-inv intfc
- Medicare policy
- LCD L33718, article A52467; LCD L33800, article A52517
- Payment
- Capped rental: rented for up to 13 months, then the patient owns it
- Prior authorization
- Not required by Medicare
- Face-to-face and order before delivery
- Not on the CMS list. The LCDs require their own in-person evaluations.
- Last checked
- November 11, 2026
What the code covers
E0470 is a bi-level device that lets the practitioner set separate pressures for breathing in and breathing out, delivered through a mask. It has no timed backup breath. A device with a backup rate is E0471, which Medicare does not cover when the primary diagnosis is obstructive sleep apnea.
Which policy applies depends on the diagnosis:
- Obstructive sleep apnea falls under the PAP LCD (L33718), the same policy as CPAP.
- Other conditions fall under the Respiratory Assist Devices LCD (L33800): restrictive thoracic disorders, central or complex sleep apnea, hypoventilation syndrome, and chronic respiratory failure caused by COPD. Each has its own test and timing requirements, which this page does not cover.
When Medicare covers it for sleep apnea
E0470 is covered for obstructive sleep apnea when the patient meets every CPAP criterion and one more:
- An in-person clinical evaluation by the treating practitioner before the sleep test.
- A qualifying sleep test: AHI or RDI of 15 or more events per hour with at least 30 events, or 5 to 14 events per hour with at least 10 events plus documented symptoms or conditions listed in the LCD.
- Instruction from the supplier on using the device.
- A CPAP (E0601) was tried and proven ineffective, during a facility titration or at home. Ineffective means it failed to meet therapy goals despite proper mask fit and appropriate pressure settings.
Before switching from CPAP to E0470, the treating practitioner must document that the mask fits and is used without difficulty, and that the current CPAP pressure is not tolerated and lower pressures failed to control symptoms, improve sleep or reduce the AHI or RDI.
If the switch happens during the first CPAP trial, no new evaluation or sleep test is needed. If the patient used CPAP for more than three months before the switch, a new in-person evaluation is needed, but not a new sleep test, and a new three-month trial starts.
Continued coverage after three months works as it does for CPAP: an in-person re-evaluation and an adherence report of 4 hours or more per night on 70% of nights in a 30-day period. The LCD gives extra timing rules when E0470 replaces CPAP partway through the trial.
What the order and records need
- A standard written order with the patient’s name or MBI, the order date, the item, the quantity if applicable, and the treating practitioner’s name or NPI and signature.
- The in-person evaluation, the sleep test report and the CPAP trial notes showing why CPAP failed.
- The re-evaluation and adherence report for month four onward.
- Proof of delivery.
There is no certificate of medical necessity, prior authorization or face-to-face list requirement for E0470.
Modifiers
- RR with KH, KI and KJ for the rental months.
- KX only when the coverage criteria of the policy that applies are met, GA with a valid ABN when they are not, or GZ without one. Lines without one of them are rejected.
Rental or purchase
E0470 is a capped rental item. Medicare pays monthly rentals for up to 13 months of continuous use, and then the patient owns it.
Why claims get denied
- E0470 was billed for sleep apnea without a documented, failed CPAP trial. It is denied as not reasonable and necessary, a medical necessity denial like CO-50.
- E0471 was billed with a sleep apnea diagnosis, which the PAP LCD says is denied. Diagnosis mismatches are explained under CO-11.
- The re-evaluation or adherence report is missing for month four onward.
- KX, GA or GZ is missing.
Sources
Last checked November 11, 2026 against the documents below. These are the Medicare fee-for-service rules that the DME MACs (Noridian and CGS) apply. Medicare Advantage plans, Medicaid and commercial payers set their own rules, so requirements can differ by payer. Policies change, so check the current version before you rely on a detail.
- LCD L33718: Positive Airway Pressure (PAP) Devices for the Treatment of Obstructive Sleep Apnea
- Policy Article A52467: Positive Airway Pressure (PAP) Devices for the Treatment of Obstructive Sleep Apnea
- LCD L33800: Respiratory Assist Devices
- Policy Article A52517: Respiratory Assist Devices
- CGS documentation checklist: Respiratory assist device E0470
- CGS documentation checklist: PAP devices for obstructive sleep apnea
- Policy Article A55426: Standard Documentation Requirements for All Claims Submitted to DME MACs
- CMS HCPCS quarterly update (official code descriptors)
- CMS DMEPOS fee schedule (payment category of each code)
- CMS Required Prior Authorization List
- CMS Required Face-to-Face Encounter and Written Order Prior to Delivery List
Run your revenue cycle as workflows.