E0601: CPAP device. What Medicare needs on the order
E0601 is a continuous positive airway pressure (CPAP) device, including auto-titrating CPAP. Medicare covers it for obstructive sleep apnea after an in-person evaluation and a qualifying sleep test, and keeps paying after month three only if the patient uses it and benefits.
HCPCS E0601
- Official description
- Continuous positive airway pressure (cpap) device
- Short descriptor
- Cont airway pressure device
- Medicare policy
- LCD L33718, article A52467
- Payment
- Capped rental: rented for up to 13 months, then the patient owns it
- Prior authorization
- Not required by Medicare
- Face-to-face and order before delivery
- Not on the CMS list. The LCD requires its own in-person evaluation before the sleep test.
- Last checked
- November 11, 2026
What the code covers
E0601 is a single-level continuous positive airway pressure device. It delivers one steady air pressure through tubing and a mask to keep the airway open during sleep. The Policy Article says auto-titrating CPAP devices are also billed as E0601. Masks, tubing, filters and the humidifier are billed with their own codes.
When Medicare covers it
Medicare covers E0601 for obstructive sleep apnea when all three of these are true:
- The patient had an in-person clinical evaluation by the treating practitioner before the sleep test, to assess them for obstructive sleep apnea.
- The sleep test qualifies. Either the apnea-hypopnea index (AHI) or respiratory disturbance index (RDI) is 15 or more events per hour, with at least 30 events, or it is 5 to 14 events per hour, with at least 10 events, and the record documents excessive daytime sleepiness, impaired cognition, mood disorders or insomnia, or hypertension, ischemic heart disease or a history of stroke.
- The supplier taught the patient or caregiver how to use and care for the device.
The sleep test can be a facility polysomnogram or a home sleep test, but it must be ordered by the treating practitioner, approved by the FDA as a diagnostic device and run by an entity that qualifies as a Medicare provider of sleep tests. A DME supplier may not perform any part of a home sleep test, including delivering or picking up the device.
Continued coverage after month three. Between day 31 and day 91 after therapy starts, the treating practitioner must re-evaluate the patient in person and document that symptoms improved and that the patient is adherent. Adherence means use of 4 hours or more per night on 70% of nights during a consecutive 30-day period in the first three months, shown by a download or a visual check of the device’s usage data that the practitioner reviews. If the re-evaluation happens after day 91 but shows benefit and adherence, coverage restarts from the date of that visit.
A patient who fails the 12-week trial can qualify again only after a new in-person evaluation and a repeat sleep test in a facility.
What the order and records need
- A standard written order before the claim is sent: the patient’s name or Medicare Beneficiary Identifier, the order date, a description of the item (a general description, the HCPCS code, its narrative or a brand and model), the quantity if applicable, and the treating practitioner’s name or NPI and signature.
- The in-person evaluation note, dated before the sleep test. The Policy Article lists what it commonly covers: snoring, daytime sleepiness, observed apneas, how long symptoms have lasted, an Epworth Sleepiness Scale, and an exam with neck circumference and body mass index.
- The sleep test report, with the AHI or RDI and the event count.
- The re-evaluation note and the adherence report for month four onward.
- Proof of delivery, which every DME claim needs.
There is no certificate of medical necessity (CMN) for E0601. CMS stopped requiring CMNs for dates of service on or after January 1, 2023. Medicare does not require prior authorization for E0601, and it is not on the CMS face-to-face list.
Modifiers
- RR for the rental, with KH on the first month, KI on months two and three, and KJ on months four through thirteen.
- KX on months one to three only if the initial coverage criteria are met, and from month four only if the continued coverage criteria are also met.
- GA if criteria are not met and the patient signed a valid Advance Beneficiary Notice (ABN), or GZ if there is no ABN. Lines without KX, GA or GZ are rejected as missing information.
- EY if the item was billed without a signed and dated order.
Rental or purchase
E0601 is a capped rental item on the DMEPOS fee schedule. Medicare pays monthly rentals for up to 13 months of continuous use, and then the patient owns the device. The reasonable useful lifetime is 5 years. A replacement after 5 years needs a new in-person evaluation showing the patient still uses and benefits from it, but no new sleep test.
Why claims get denied
- The sleep test or the in-person evaluation does not meet the LCD. The claim is denied as not reasonable and necessary, which is a medical necessity denial like CO-50.
- The day 31 to 91 re-evaluation or the adherence report is missing, so month four onward is denied.
- KX, GA or GZ is missing, so the line is rejected. See CO-4 for modifier denials, and MA130 for claims returned as unprocessable.
- The supplier billed before it had a complete standard written order, or cannot show proof of delivery.
Sources
Last checked November 11, 2026 against the documents below. These are the Medicare fee-for-service rules that the DME MACs (Noridian and CGS) apply. Medicare Advantage plans, Medicaid and commercial payers set their own rules, so requirements can differ by payer. Policies change, so check the current version before you rely on a detail.
- LCD L33718: Positive Airway Pressure (PAP) Devices for the Treatment of Obstructive Sleep Apnea
- Policy Article A52467: Positive Airway Pressure (PAP) Devices for the Treatment of Obstructive Sleep Apnea
- CGS documentation checklist: PAP devices for obstructive sleep apnea
- 42 CFR 414.229: capped rental items
- Policy Article A55426: Standard Documentation Requirements for All Claims Submitted to DME MACs
- CMS HCPCS quarterly update (official code descriptors)
- CMS DMEPOS fee schedule (payment category of each code)
- CMS Required Prior Authorization List
- CMS Required Face-to-Face Encounter and Written Order Prior to Delivery List